Charge Exchange Recombination Spectroscopy Based on Diagnostic Neutral Beam in Ht-7 Tokamak

Shi Yuejiang,Fu Jia,Li Yingying,William Rowan,Huang He,Wang Fudi,Gao Huixian,Huang Juann,Zhou Qian,Liu Sheng,Zhang Jian,Li Jun,Xie Yuanlai,Liu Zhimin,Huang Yiyun,Hu Chundong,Wan Baonian
DOI: https://doi.org/10.1088/1009-0630/12/1/03
2010-01-01
Abstract:Charge exchange recombination spectroscopy (CXRS) based on a diagnostic neutral beam (DNB) installed in the HT-7 tokamak is introduced. DNB can provide a 6 A extracted current at 50 kV for 0.1 s in hydrogen. It can penetrate into the core plasma in HT-7. The CXRS system is designed to observe charge exchange (CX) transitions in the visible spectrum. CX light from the beam is focused onto 10 optical fibers, which view the plasma from -5 cm to 20 cm. The CXRS system can measure the ion temperature as low as 0.1 keV. With CXRS, the local ion temperature profile in HT-7 was obtained for the first time.
What problem does this paper attempt to address?