Determination of Sirolimus in Rat Whole Blood by HPLC-MS/MS

SUN Ming-hui,SI Lu-qin,ZHAI Xue-zhen,LING Jing,YANG Xiang-liang
2010-01-01
Abstract:OBJECTIVE To develop a HPLC-MS/MS method for the determination of sirolimus in rat whole blood. METHODS Sirolimus and internal standard testosterone were extracted from whole blood with liquid-liquid extraction, then separated on a Phenomenex Luna C_(18) column(2.0 mm x 250 mm ,5μm)at the flow-rate of 0.25 Ml·min~(-1). The mobile phase was methanol-water(90:10) and the column temperature was 55 ~C. Eleetrospray ionization(ESI) source was applied and operated in the positive ion mode.Multiple reaction monitoring (MRM) mode with the transitions of m/z 936.6→409.2 and m/z 345.4→109.1 were used to quantify sirolimus and the internal standard, respectively. RESULTS The linear calibration curve was obtained in the concentration range of 0.54~108.00 μg ·L~(-1). The low limit of quantification was 0.54 μg · L~(-1). The inter- and intra-day precisions (RSDs) were less than 12%. CONCLUSION The method has been proved to be specific, sensitive, rapid and suitable for the pharmacokinetic study of sirolimus in rats.
What problem does this paper attempt to address?