Study of the Removal of Manganese from Water with an Ion-exchange Membrane Without External Voltage Application

谢德华,施周,陈世洋,谢鹏,宋勇
2010-01-01
Abstract:The removal of manganese ion from water with an ion-exchange membrane under no external voltage condition was studied,and the effects,such as manganese ion concentration,the concentration of compensation potassium ions,water stirring speed,temperature and hydraulic retention time(HRT) on the removal efficiency of manganese ions were also evaluated.The results have shown that,when the initial concentration of bivalent ion Mn2+ is 0.0727 mmol/L(4 mg/L),under the experimental conditions of the water temperature of 25 ℃,HRT of 6 h,hydraulic mixing speed of(600±25) r/min,and the concentration of the compensation ion K+ is 20 times that of Mn2+,the removal efficiency of 80% for the manganese can be achieved.In addition,with the equipments unchanged,when the inlet concentration of manganese increases to 0.727 mmol/L(40 mg/L),the removal efficiency will be lowered to 66%;while the ratio of the concentration of compensation potassium ions to that of inlet manganese is higher than 20,the removal efficiency will not change significantly,if the ratio continues to increase;by lowering the stirring speed to(300±25) r/min,the removal efficiency will be decreased to 51%;by lowering the temperature to(16±1) ℃,the removal efficiency is 60%;when the hydraulic retention time(HRT) is more than 6 h,the removal efficiency will not undergo any significant change by increasing HRT to 12 h.
What problem does this paper attempt to address?