Different Post-Processing Techniques in Evaluating Stenosis Degree of Vessels in Static Model of Coronary Artery Stenosis

YU Ming-chuan,FEI Sheng-min,LI Jing
DOI: https://doi.org/10.13929/j.1003-3289.2010.09.072
2010-01-01
Abstract:Objective To observe the value of different post-processing techniques in the diagnosis of vessels stenosis with CT scanning of the static model of coronary artery stenosis. Methods A roll of bandage and a plastic bag filled with diluted contrast medium were used to simulate the lung and the heart. Flour, butter and paraffin were mixed to make the simulative atherosclerosis plaques. Plastic tube with diameter of 3 mm was chosen to simulate the coronary artery. The static model of coronary artery stenosis was established. CT scanning was performed, and the images were reconstructed with curved planar reformation (CPR), multiplanar reformation (MPR) and maximum intensity projection (MIP). The stenosis degree of the simulating vessel was evaluated by 3 radiologists. Then the frozen section of the simulating vessel was observed under microscope by 1 pathologist, while the stenosis degree was measured. Results CT images of the model were similar to those of the patients with coronary artery stenosis. There was high agreement of the diagnostic results between the 3 radiologists. Significant difference was found between the accuracy in evaluating the stenosis degree with observing CPR and MPR images and that of obtained with MIP image (all P0.05). Conclusion It is extremely important to adopt suitable post-processing technique in improving the diagnostic accuracy of vessel stenosis.
What problem does this paper attempt to address?