Hydrothermal Decomposition of Polychlorinated Divenzo-p-dioxins and Dibenzofurans in Fly Ash of Medical Waste Incinerator

WANG Yufeng,LI Xiaodong,JIN Jian,YAN Jianhua
2010-01-01
Abstract:Hydrothermal treatment technology was used to remove polychlorinated divenzo-p-dioxins and dibenzofurans (PCDD/Fs) from heavily contaminated medical waste incinerator fly ash (MWIFA). The experiments were carried out in an extraction vessel with magnetic stirring. The effects of experiment parameters including S/L ratio, reaction temperature, and NaOH/ash weight ratio on decomposition of PCDD/Fs were investigated. PCDD/Fs (only 17 toxic congeners) of original and hydrothermal treated fly ash (FA) were analyzed by high-resolution gas chromatography-mass spectrometry (HRGC-HRMS). The results indicated change of S/L ratio had little effect on degradation of PCDD/Fs, while concentrations of PCDD/Fs in FA decreased largely at relatively high temperature and with alkaline ingredients. Under condition of temperature 250°C, S/L ratio and NaOH/ash weight ratio 1:10, removal efficiency for PCDD/Fs reached 99.46%. These results revealed that hydrothermal treatment was a effective technology for PCDD/Fs decomposition in FA. © 2010 Chin. Soc. for Elec. Eng.