Metering Correlation of Slotted Orifice for Low-pressure Wet Gas Flow

华陈权,王昌明,耿艳峰,王晓智
DOI: https://doi.org/10.14177/j.cnki.32-1397n.2010.01.030
2010-01-01
Abstract:A slotted orifice in wet gas metering is required to find out a correlation to correct the liquid-induced over-reading. The wet gas response of the horizontally installed slotted orifice with 0.50 beta ratio is experimentally studied. After studying the relationship between the over-reading and Lockhart-Martinelli parameter, gas Froude number, the gas to liquid density ratio, a novel metering correlation for low-pressure wet gas flow is given. The results show that the new correlation corrects the liquid induced gas flow rate prediction error of the wet gas flow to ±4% at a 97% confidence level, with the conditions of pressure from 0.25 MPa to 0.35 MPa, Lockhart-Martinelli parameter from 0.02 to 0.6, and the gas Froude number from 0.5 to 2.7, which is distinctly more precise than other correlations of the slotted orifice.