Thermal-Hydraulic Analysis of Sub-channel on ADS Principle Verification Device

刘展,杨燕华
2010-01-01
Abstract:The present paper performs the steady-state thermal-hydraulic analysis of sub-channel on ADS principle verification device using the COBRA-TF code. The calculation results from COBRA-TF code are proved fully consistently by RELAP5,which shows that the results about the steady-state thermal-hydraulic analysis are correct,and it provides the basic research on the design of ADS principle verification device and safety.