Development and Assessment of a Sub-Channel Code Applicable for Trans-Critical Transient of SCWR

X. J. Liu,T. Yang,X. Cheng
DOI: https://doi.org/10.1016/j.nucengdes.2013.05.026
IF: 1.7
2013-01-01
Nuclear Engineering and Design
Abstract:In the last few years, extensive R&D activities have been launched covering various aspects of super-critical water-cooled reactor (SCWR), especially the thermal-hydraulic analysis. Sub-channel code plays an indispensable role to predict the detail thermal-hydraulic behavior of the SCWR fuel assembly. This paper develops a new version of sub-channel code COBRA-SC based on the previous COBRA-IV code. The supercritical water property and heat transfer/pressure drop correlations under supercritical pressure are implemented to this code. Moreover, in order to simulate the trans-critical transient (the pressure undergo a decrease from the supercritical pressure to the subcritical pressure), pseudo two-phase method is employed in COBRA-SC code. This work is completed by introduction of a virtual two-phase region near the pseudo-critical line. A smooth transition of void fraction can be realized. In addition, several heat transfer correlations right underneath the critical point are introduced into this code to capture the heat transfer behavior during the trans-critical transient. Some experimental data from simple geometry, e.g. the single tube, small rod bundle, is used to validate and evaluate this new developed COBRA-SC code. The predicted results show a good agreement with the experimental data, demonstrating good feasibility of this code for SCWR condition. A code to code comparison between COBRA-SC and ATHLET for a blowdown transient of a small fuel assembly is also presented and discussed in this paper. (C) 2013 Elsevier B.V. All rights reserved.
What problem does this paper attempt to address?