Design and Characterization of a Large-Area Integrating Sphere Uniform Radiation Source for Calibration of Satellite Remote Sensors

Yingwei He,Ping Li,Guojin Feng,Yu Wang,Zilong Liu,Chundi Zheng,Houping Wu,Xiaoying Zong,Yufeng Zhang,Yongqiang Li,Dingguo Sha
DOI: https://doi.org/10.1117/12.863270
2010-01-01
Abstract:The large field of view (FOV) imaging radiometers performed as remote sensors are extensively used in remote sensing and surveillance applications. The pre-launch test and radiance calibration of large FOV imaging remote sensors have resulted in the development of calibration techniques. One of these calibration techniques is the employment of large-area integrating sphere radiation sources as radiance transfer standards. To meet the calibration requirements of large FOV imaging remote sensors, a large-area integrating sphere uniform radiation source (ISURS) based on a 1600 mm diameter internally illuminated integrating sphere with a 620 mm diameter exit port is designed and manufactured. This large-area integrating sphere radiation source has been used for pre-launch calibration of large FOV imaging remote sensors which fly aboard Erath-observing satellites.Design criteria of large-area ISURS including sphere source radiance output, spatial radiance uniformity and radiance stability are presented. Optical theories used to predict the radiance output of the ISURS at the exit port for a specific incident spectral flux are discussed. Integrating sphere internal lamp sources specifications and sphere coating selection are concerned to suit the requirements of the multi-spectral-band imaging remote sensors. An optical software TracePro based on the ray-tracing method is used to simulate the spatial radiance uniformity at the exit port of sphere source. This work reveals that the angle of the internal lamp source from the centre of the sphere is an important factor. An integrating sphere source model is established to take this factor into account, and to increase the design efficiency of the large-area sphere radiation source.The spectral radiance of this large-area ISURS is characterized in the wavelength region from blue to near-infrared spectral band. The spatial radiance uniformity measurement result of the large-area ISURS is 99.19% with a 0.12% deviation by simulation result of sphere source model across a 620 mm diameter exit port. The stability of the large-area ISURS is better than 0.3% over a period of 3 hours after an initial 30-minute warm up.
What problem does this paper attempt to address?