Parameter Optimization of Detecting Coil Design for Fuel Ball Counter in High Temperature Gas-Cool Reactor

ZHANG Liang,HAN Zandong
DOI: https://doi.org/10.16511/j.cnki.qhdxxb.2010.02.024
2010-01-01
Abstract:The magnetic shielding effect of the thick walled stainless steel pipe strongly reduces the detection signal of fuel ball counter sensors in the high temperature gas-cooled reactor(HTGR).Optimization of the coil parameters will improve the signal-to-noise ratio and reduce wrong or missed detection.The finite element method using ANSYS was used to analyze the influences of the stimulant frequency,number of turns,and frame parameters on the detection sensitivity.The simulations were used to develop an optimized fuel ball detection sensor for testing.The simulations and test results show that the sensor gives good performances with a frequency of 4 kHz,150 turns,and a distance between the inner and outer coils of 36 mm.
What problem does this paper attempt to address?