Ventilating simulation and geometric optimization on environmental improvement for aluminum electrolysis workshop

Jingxian Liu,Jihong Mao,Xiuli Lin,Deqiang Chang,Xi Sun
2010-01-01
Abstract:The HF gas and heat emitting from aluminum electrolysis may exert harmful impact on operator's health, thus available ventilation is the effective means to control the hazards. In order to obtain the best ventilation for 300 kA aluminum electrolysis workshop, a 3D geometric model of workshop is built. According to the theoretical analysis and preliminary calculation, some design workshop resolutions with different geometric structure are simulated using CFD method. By analyzing the results, the optimal geometry design is found, the air exchange rate per hour in the workshop is more than 43, and the ventilation volume is greater than 132 m 3/s; the concentration of HF is 0.063 mg/m 3 that is lower than national standard; the temperature on work platform is 32.5°C, operators can work in comfortable environment. The conclusions of the paper were used in factory with good practical results.
What problem does this paper attempt to address?