Field Measurement of Convective Heat Transfer on External Surface of Building Using Naphthalene Sublimation Method

Jing LIU,Zhi-peng FU,Jian-tao SHAO,Wen-wu ZHANG
DOI: https://doi.org/10.3969/j.issn.0493-2137.2009.08.005
2009-01-01
Abstract:The convective heat transfer coefficient (CHTC) on external surface of building is the important parameter in building energy conservation and urban environment. A method using naphthalene sublimation technique for measuring CHTC was developed which was also applied in field measurement on the horizontal roof of a building. By means of comparison between naphthalene sublimation and eddy correlation, the results of both methods tend to be same. The results were not seriously affected by the variation of surface temperature of naphthalene and the temperature difference between roof surface and above air. The accuracy of this method was also analyzed. Finally, a correlation for calculating CHTC of external surface of building was obtained based on measurement data. The results show that the naphthalene sublimation is an effective method for measuring CHTC of external surface of building.
What problem does this paper attempt to address?