An Integrated Opc Based Test Bench System For Multi-Mw Permanent Magnet Synchronous Generator For Wind Turbine

Dong Xingjian,Zhuang Shenxian,Yan Wen
DOI: https://doi.org/10.1109/SUPERGEN.2009.5348126
2009-01-01
Abstract:An Integrated OPC based test system for Multi-MW permanent magnet synchronous generator for wind turbine is designed and realized. The Profibus-DP and OPC interface are adopted to be the communication network and the software communication interface for this system, respectively. Three ABB ACS800 converters are involved and served as the power units. The hardware configuration using SIEMENS Profibus-Dp master card CP5613A2 and the software diagram are given. Three different tests were carried out by this system. The reliability and utility are proved through testing results.
What problem does this paper attempt to address?