The infection of the opening of the electronic expansion valve on PV/T-SAHP system

Haitao Wang,Jie Ji,Gang Pei,Wei He
2009-01-01
Abstract:Fixing the frequency of compressor, under different opening of Electronic Expansion Valve(EXV), outdoor tests were conducted on the PV-SAHP system. The dynamic behavior of PV-SAHP was analyzed. The COP of the system reduced along with the raising of temperature of the condensing water. The peak value of the photovoltaic efficiency is occurred while the balance between the cooling influence of the vaporizing working material to the PV module and the heating influence of the air to the collector/evaporator, not the vertex of the solar radiation. The power vibration of the compressor appeared when the raising of the solar radiation at a fixing opening of EXV, and the vibration was especially evident at the maximum opening of the EXV. Therefore, the stability principal of the PV-SAHP system was put forward. At the same time, it was found that the key of the PV/T-SAHP study is to discover the relation between the solar radiation and the superheat of collector/evaporator.