Detection of distributor dead-zone in gas-solid fluidized bed by acoustic emission method

REN Cong-jing,WANG Jing-dai,YANG Yong-rong,CHEN Jie-xun
DOI: https://doi.org/10.3785/j.issn.1008-973X.2009.03.015
2009-01-01
Abstract:Acoustic signals originated from particles impact on the distributor of the gas-solid fluidized bed were collected by the transducer located under the distributor. By analysing the signals with frequency spectrum analysis and comparing with experiment phenomenon, it was found that the acoustic energy can reflect the distribution of the defluidized area. As the energy was smaller when the area corresponding to the sample point exsited defluidization, a criterion to detect defluidization was presented. The criterion was that when the ratio of energy between the sample point and the largest value point was smaller than 0.4, there was defluidization in the fluidized bed. Experiments were carried out in the gas-solid bed with the static bed height of 20 and 800 mm, and the result showed that this criterion was suitable for the online measurement of defluidization. Ultimately a facile, sensitive, exact and on-line way to detect defluidization was acquired, which was applicable to the industry.