Acoustic emission and agglomeration location in gas-solid fluidized bed

Xian-bo YU,Cong-jing REN,Xiao-jing JIANG,Jing-dai WANG,Yong-rong YANG
DOI: https://doi.org/10.3785/j.issn.1008-973X.2008.10.034
2008-01-01
Abstract:Real time detection of agglomeration on the wall of fluidized bed reactors was implemented using the acoustic emission technique to analyze acoustic energy changes. The attenuation law of the acoustic wave for polyethylene particles and the effective distance was presented according to the experiment of single particle colliding to the glass plate. Acoustic signals of particles along the axis and round of the exterior surface with or without agglomeration adhering to the inner surface were investigated in the gas-solid fluidized bed with 150 mm in diameter. The energy distribution under normal condition was taken as a norm to determine the agglomeration location based on energy analysis. When the real time energy distribution performs abnormal low ebb, the zone difference of acoustic effective distance and low ebb corresponds to the axial location of agglomeration; while the radial energy distribution is anisomerous, the average energy is less and the standard difference is larger, the agglomeration takes place and the continuous zone having lower average energy and larger relative error is the radial position of agglomeration.
What problem does this paper attempt to address?