Virtual Flux in a Three-Level Pulse Width Modulation Rectifier

ZHANG Yingchao,ZHAO Zhengming,ZHANG Yongchang,LU Ting,YUAN Liqiang
DOI: https://doi.org/10.3321/j.issn:1000-0054.2009.01.007
2009-01-01
Abstract:Sensorless control gives higher reliability and economic benefits.This paper describes a method to calculate the virtual flux for a three-level pulse width modulation(PWM) rectifier.Then,two control strategies are given for a three-level pulse width modulation rectifier without power source sensors based on the virtual flux.Pre-calculation of the virtual flux and a soft-startup control scheme were used to reduce excessive surge currents during system startup.Experimental results show that the scheme can be easily applied to control a three-level pulse width modulation rectifier without power source voltage sensors,and that the startup current is reduced about 50% by the soft-start process.