Biosensor for hydrogen peroxide based on chitosan and nanoparticle complex film-modified glassy-carbon electrodes

Qiao Xu,Jianhua Wang,Zhan Wang,Haiqiao Wang,Qin Yang,Yuandi Zhao
DOI: https://doi.org/10.1080/00032710903082739
2009-01-01
Analytical Letters
Abstract:A biosensor for hydrogen peroxide was fabricated by co-immobilizing cadmium telluride (CdTe) nanoparticles, chitosan, and hemoglobin (Hb) matrix. There was a pair of nearly reversible redox peaks around -0.360V, and the electrochemical behavior of Hb was a surface-controlled process, with an electron-transfer rate constant of 1.36s-1 and surface coverage of 2.62x10-10mol cm-2. Fourier transform infrared (FT-IR) spectra and ultraviolet-visible (UV-vis) spectra indicated that Hb sustained its natural conformation. It was demonstrated that Hb in the matrix kept its bioactivity and exhibited catalytic ability toward H2O2, with a response ranging from 7.44x10-6 to 6.95x10-4M and a detection limit of 2.23x10-6M.