Study on the Reactive Characteristics of Simultaneous Removal of SO2 and NOx by Corona Discharge Radical Shower System

WU Zu-liang,GAO Xiang,LI Ji-wu,SUN Pei-de,LUO Zhong-yang,CEN Ke-fa
DOI: https://doi.org/10.3321/j.issn:1003-9015.2008.02.026
2008-01-01
Abstract:The reactive characteristics and mechanism of the process of removing SO2 and NOx simultaneously via using the corona discharge radical shower technology were studied. The results show that the SO2 removal is dependent on the thermal reaction with the ammonia in the gas injection, and the radical reactions can further improve its removal at a certain extent. However, the NOx removal depends on the corona discharge process mainly, and the radical reactions of NH, NH2 and OH and the reactions between sulfites and NO2 also play important roles in removing NOx. It was found that the increase of NH3 content in the injection gas can improve the removal of SO2 and NOx, while among them the NOx removal has weaker sensitivity on NH3 content than that of SO2 removal. With the increase of energy input, the input energy utilization ratio of SO2 and NOx removals decrease obviously at first, and then turn into stable when the energy input reaches and over 3 W·h·m-3.
What problem does this paper attempt to address?