Test Analysis of Stiffened T-stub Connections

ZHAO Wei,TONG Gen-shu
DOI: https://doi.org/10.3785/j.issn.1008-973x.2008.01.013
2008-01-01
Abstract:Three T-stub connections without stiffeners and six stiffened T-stub connections with varied stiffener shape and thickness were tested monotonically to investigate the effect of endplate stiffener on the stiffness and strength of T-stubs.The load carrying capacity,the relative deformations of endplates and the strains on stiffeners and endplates were measured,and the load-deformation curves of the connections and the load-strain curves were plotted.The influences of different shapes of stiffeners on loading resistance and rotational stiffness characteristic of stiffened T-stub connections were evaluated.Eventually the design method of stiffener was presented.The test results show that the commonly used stiffeners in current Chinese practice often yield or/and buckle prematurely.And the stiffener designed by the method can meet the requirement in CECS 102:2002,which demands that stiffener should be able to force the extended portion of endplates from clamped-free boundary to plates fixed on two adjacent boundaries.
What problem does this paper attempt to address?