Analysis of matrine and oxymatrine in kushensu injection by UPLC/Q-TOF-MS

Mao Ye,Guo-xiang Xie,Ai-hua Zhao,Yuan-yuan Zhang,Wei Jia
2008-01-01
Abstract:Objective: To develop a method for the determination of matrine and oxymatrine in Kushensu injection by ultra performance liquid chromatography-quadrupole time-of-flight mass spectrometry (UPLC/Q-TOF-MS). Method: The analysis was performed on a Acquity UPLC BEH C18 column (2.1 mm x 100 mm, 1.7 μm) with the gradient elution of 10 mmol·L-1 amine acetate (pH 8, adjusted by aqueous ammonia) and methanol. The flow rate was set as 0.30 mL·min-1. The column temperature was maintained at 30°C. The peaks were detected at 210 nm and the injection volume was 2 μL. Result: The calibration curves showed good linearity within the test ranges of 0.084-3.36 μg for matrine and 0.086-3.44 μg for oxymatrine, respectively. The mean recoveries were 103.2%, 98.7 %, and the RSD were 1.5%, 1.2%, respectively. Conclusion: The established method is simple, rapid and sensitive, can be used for the quality control of matrine and oxymatrine in Kushensu injection through the manufacturing process and clinical implement.
What problem does this paper attempt to address?