Development and static load tests of multi-wire carbon fiber reinforced polymer stay cables

Nian-chun DENG,Jin-ping U,Zhi ZHOU,Yue LONG,Ye-dong JIANG
DOI: https://doi.org/10.3969/j.issn.1005-0299.2008.04.005
2008-01-01
Abstract:To improve the corrosion resistance and the fatigue life of stay cables, the Carbon Fiber Reinforced Polymer(CFRP)was used for stay cables. The single-wire bond-anchorages and 7-wire bond-anchorages were developed for CFRP tendons with epoxy resin. Component assembling of stay cables with CFRP were tested. The influencing factors of bond-anchorage behaviors were induced. Results indicate that the coarseness of tendon, the interior angle of anchorage, the bond strength and the grouting pressure directly influence on anchoring. Moreover, the developed bond-anchorages have high anchor efficiency up to 95% and can be applied in civil engineering.
What problem does this paper attempt to address?