Manipulating T-Junction Chip for the Generation of Uniform O/W and W/O Emulsions

Chia-Hsien Yeh,Sheng-Ji Lee,Meng Sun,Qun Fang,Yu-Cheng Lin
DOI: https://doi.org/10.1117/12.771516
2008-01-01
Abstract:The purpose of this study is to generate monodisperse oil-in-water (O/W) and water-in-oil (W/O) emulsions using microfluidic T-junction. The materials of poly methyl methacrylate (PMMA) (hydrophobic), polydimethylsiloxane (PDMS) (hydrophobic) and glass (hydrophilic) were employed for microfluidic chip fabrication. Our strategy is based on the shear focus effect and sheath effect (focusing) to form uniform self-assembling sphere structures, the so-called O/W and W/O emulsions, in the T-junction microchannel. Results show that the size from 31 mu m to 43 mu m in diameter of O/W emulsions was generated by using the glass-based microfluidic chip. In addition, results show that the size from 70 mu m to 220 mu m of W/O emulsions was available by utilizing the PMMA-based microfluidic chip. These W/O emulsions were further applied to Ca-alginate microparticles (Ca-alg MPs). And the results also show that the size from 410 mu m to 700 gin of UV-Photopolymerized microparticles was available by utilizing the PDMS-based microfluidic chip. The proposed microfluidic chips are capable of generating relatively uniform micro-droplets and have the advantages of actively controlling the droplet diameter, and having a simple and low cost process, with a high throughput.
What problem does this paper attempt to address?