The hybrid control for the double-direction decoupling platform interacting with the structure
LIU Hong-jun,LIU Jie,CHENG Jiang
DOI: https://doi.org/10.3969/j.issn.1004-4523.2012.02.011
2012-01-01
Abstract:For the traditional hybrid control vibration isolation platform, because of the interaction between the vertical direction and the horizontal one, it becomes difficult to be applied in practical engineering. Thus, in this paper a new vibration isolation platform is firstly proposed, for which, the two directions are uncoupled and the platform is then set to a three story factory model. And the numerical analysis is done for the uncontrolled structural floor response and the passive control isolation platform response to verify the reasonableness and configurability of the model. Then, the comparative analysis is done, through which, the influence of the integration control of the platform with the coupling structure upon the time history response is disclosed. The results show that for the high precision micro-vibration control, the double-direction decoupling platform can greatly simplify control design system and the integration control is conducive to further deepening and optimal control design. Finally, one-third octave spectrum is used to analyze the response of the velocity under uncontrolled, passive and hybrid control in the frequency domain, the results show that the hybrid control scheme can achieve full frequency vibration isolation.