Research on Heat Transfer Performance of Flat Plate Pulsating Heat Pipe Based on Central Compound Design

傅烈虎,王瑞祥,李青冬,吴业正
DOI: https://doi.org/10.3321/j.issn:0253-987x.2008.09.009
2008-01-01
Abstract:The experiment on heat transfer performance of flat plate pulsating heat pipe(PHP) was designed based on the central compound design.A second order regression model with variables including charge liquid rate,inclined angle,and heat quantity was obtained from the experiment data,and the deviation was within 5% between statistical regression values and the experiment values.The results show that transfer heat resistance of PHP was sensitive to the square of inclined angle and square of heat quantity,and it was also impacted by the arithmetic product of charge liquid rate or inclined angle and heat quantity.In addition,there was not obvious directly correlation between charge liquid rate and incline angle impacted on heat transfer performance of PHP in statistics.The conclusion can be drawn that the optimal heat transfer performance of PHP can be achived by solving for extremum of regression model.
What problem does this paper attempt to address?