Kirschner wire technique for pedicle screw insertion in thoracic scoliosis:Accuracy evaluation

Ding-jun Hao,Bao-rong He,Qi-ning Wu,Jin-song Zhou,Xiao-dong Wang,Tuan-jiang Iju,Zong-rang Song,Zeng-liang He,Hua Guo
DOI: https://doi.org/10.3321/j.issn:1673-8225.2008.26.007
2008-01-01
Abstract:BACKGROUND: Insertion of pedicle screws into vertebra thoracalis determines the success of scoliosis correction. OBJECTIVE: To observe the methods and results of screw insertion and histocompatibility of host using Kirschner wire plus tapping technique. DESIGN, TIME AND SETTING: Retrospective case analysis was performed at Department of Spinal Surgery of Xi’an Red Cross Hospital from January 2000 to January 2005. PARTICIPANTS: 129 cases underwent pedicle screw implantation to correct thoracic scoliosis using Kirschner wire plus tapping technique. 103 patients were followed up, including 42 males and 61 females, with a median age of 15.3 years (range 13 to 19 years). METHODS: Cortical bone at screw entrance site was removed with rongeur forceps. According to the preoperative depth and rotation measured by radiographs and CT, 1.5 mm and 2.5 mm Kirschner wires were used to drill holes along pedicle until achieving the depth. The hole was detected using specillum followed by awl entrance. After rechecking the hole using specillum, the screws were inserted. MAIN OUTCOME MEASURES: Blood vessel injury, leakage of cerebrospinal fluid and position of screws; accuracy of screws; correction degree on coronal plane, sagittal plane and rotation deformity; biocompatibility of materials to host. RESULTS: 96.2% was successful inserted by one time. There were 32 screws with wrong direction and 18 screws were found during the operation; 5 of screws were medial, 3 were below, 4 were superior, and 6 were lateral; 14 lateral screws were found by CT or X-ray postoperatively. One with leak of cerebrospinal fluid in operation was blocked by bone wax and no leak of cerebrospinal fluid occurred after surgery. There were no patients with spinal cord injury and leakage of cerebrospinal fluid and no infection of incisional wound. Razor back deformity was obvious improved and body height was increased 4.6 cm after surgery. The Cobb angle at coronal plane was 21°after surgery and correction rate was 73%. The Cobb angle in sagittal plane was 23°. Rotation deformity was corrected Ⅰ to Ⅱ degree. The patients were followed-up for averagely 3.5 years. The correction lost was 1.8% at the final follow-up. One case developed delayed infection; 4 developed screw breakage, and 1 developed lateral screw worsen. CONCLUSION: Kirschner wire technique enables accurate implantation of pedicle screws and leads to few complications.
What problem does this paper attempt to address?