Abstract:Atmospheric pressure glow discharge (APGD) is usually realized in the form of dielectric-barrier discharge (DBD). An effective method to get APGD is to reduce the electric breakdown field. So it is useful to analyse the factors that affect the critical breakdown strength in gas discharge. Some influencing factors, including the gas type, gas pressures, power supply frequency, and flow speed, were experimentally studied. It is concluded that the breakdown strength decreases as the gas pressure is reduced, while the influence of power supply frequency is not obvious and the influence of flow speed differs with the types of gases. It seems that the gas type, gas pressure, frequency and the distance between two electrodes have a combined influence on the discharge. Some elementary analyses are carried out in the end.
What problem does this paper attempt to address?