Measurement of anterior segment in myopic eyes with Pentacam scheimpflug system

Yanling He,Li Yuan,Xiaoxin Li,Yiwen Hu
DOI: https://doi.org/10.3760/cma.j.issn.2095-0160.2007.11.019
2007-01-01
Abstract:Objective: To compare the biological parameters of normal and myopic eyes with Pentacam system and establish the preliminary data of various degree of myopic eyes. Methods: Repeatability was determined from 3 successive measurements of 50 healthy eyes with Pentacam system. Pentacam scheimplug imaging system was used to measure the anterior segment on 523 cases (1 024 eyes). Measured eyes were divided into emmetropia (240 eyes), low myopia (280 eyes), moderate myopia (272 eyes) and high myopia (232 eyes) according to the mean spherical equivalent. Results: The variations of ocular anterior segment were as follows in 50 healthy eyes: coefficient of cornea anterior keratometry 0.30%, posterior keratometry 0.64%, corneal apical pachymetry 0.70%, central anterior chamber depth (ACD) 0.70%, cornea volume 0.81%, anterior chamber volume 1.98%, anterior chamber angle 2.68%, pupil diameter 4.73%. The anterior keratometry elevated from (43.34 ± 1.46) D to (43.83 ± 1.28) D and pupil diameter decreased from (3.13 ± 0.65) mm to (2.92 ± 0.43) mm with the increase of myopic diopter of eyes (P < 0.05, P < 0.05). The other biometric data had no statistically significant difference among the four groups (P > 0.05). Conclusion: Pentacam scheimpflug system can provide rapid, simple and accurate measurement to ocular anterior segment, which is helpful in establishing standards of anterior segment of eyes.