Correlation analysis between myopic refraction and ocular components

Qin Wu,Baisheng Xu,Yangshun Gu
DOI: https://doi.org/10.3760/cma.j.issn.1006-4443.2015.01.011
2015-01-01
Abstract:Objective To investigate the relationship between myopic refraction and ocular components.Methods Retinoscopy was performed in 533 myopic subjects (1018 eyes).K value was measured by corneal mapping,and A/B ultrasound scan to get AL,ACD and LT.VCD,AnL,RLT/AL and RAL/R were calculated.Results In myopia,AL was not associated with LT (r =0.028,P =0.364); SEQ and AL,ACD,LT,K,VCD,RAL/R,RLT/AL were all significantly correlated (P <0.01),and better associated with RAL/R,A1 and VCD (r =-0.815;-0.624;-0.619); ACD,LT and AnL were not statistically different between myopia groups (ANOVA:P =0.153; 0.063; 0.625),nonetheless,all the other parameter did (P <0.01).Conclusions Myopic severity can be featured by the significant difference of posterior segment measurement,the anterior segment is comparatively stable and statistical insignificant.
What problem does this paper attempt to address?