Effect of Height to Width Ratio at Entrance and of the Straight Section's Height on the Performance of Rectangular Shaped Cyclone Separators

WANG Yu-zhao,HOU Xiang-song,WU Yu-xin,WANG Jin-wei,LI Shao-hua
DOI: https://doi.org/10.3969/j.issn.1674-7607.2007.02.008
2007-01-01
Abstract:15 rectangular shaped cyclone separators provided,with an acceleration section have been designed for different height to width(a/b) ratio at entrance and different heights(h) of the straight section;the edge length(D) of all the straight sections remaining constant while the height to width ratio of the entrance varies between 3.8~10.6 and height of the straight section varies between 1.8 D~2.8 D.Their separation efficiencies and flow resistances were all measured,under the same operating conditions,in a large scale cold state test rig.Results indicate that,with increasing height to breadth ratio of the entrance,the separation efficiency first rises and then drops,getting maximal for a ratio a/b=8;while,with the straight section's increasing height,it first drops and then rises,arriving at a minimum at h=2.3 D.On the other hand,the separator's flow resistance rises with increasing height to breadth ratio at entrance and drops with decreasing height of the straight section;the optimal values being respectively a/b=8 and h=1.8 D;the corresponding pressure drop being 1.22 kPa.Figs 9,table 1 and refs 10.
What problem does this paper attempt to address?