A Sub-1V Picowatt Voltage Reference with Improved PSRR and Line Sensitivity for Wearable Biomedical Applications
Yilun Jin,Yuhang Zhang,Lining Hu,Zhiwen Gu,Jian Zhao,Yan Liu,Yongwei Lou,Yongfu Li,Zhihong Luo,Yanhan Zeng
DOI: https://doi.org/10.1007/s10470-023-02187-3
IF: 1.321
2024-01-01
Analog Integrated Circuits and Signal Processing
Abstract:This paper presents a picowatt voltage reference circuit using a voltage regulation scheme consisting of a self-regulation native N-type transistor, a double regulation topology formed by a stacked structure of two native N-type transistors, and a P-type transistor-based self-biased current source, to feed a diode-connected P-type load and a PNP transistor load. This improves the line sensitivity and the power supply rejection ratio (PSRR) without the use of an on-chip capacitor. The circuit is designed in a 180 nm CMOS process with an area of 13,700 μm2 and operates with a minimum supply voltage of 0.8 V. Post layout simulation results show that the circuit provides a constant output voltage of 160.2 mV with a temperature coefficient (TC) of 151.6 ppm/ ^∘ C from 0 to 100 ^∘ C, a line sensitivity of 0.00114 - 72.6 dB at 100 Hz, and an untrimmed voltage accuracy ( / ) of 0.99