Full Scale Experimental Study on Fire Behavior of Plywood Lining in Enclosure and Corresponding Model Simulation

XU Liang,ZHANG He-ping,YANG Yun
DOI: https://doi.org/10.3321/j.issn:1006-8740.2006.05.009
2006-01-01
Abstract:Plywood with the thicknesses of 3mm,5mm,9mm and 12mm respectively,was chosen to be tested for full- scale experimental study on fire bedavior of playwood lining in the ISO 9705 room (3.6m×2.4m×2.4m).Heat release rate and flashover time were obtained,from which the effects of the thickness of the plywood on fire development were ana- lyzed.Meanwhile,wind-aided flame spread model was introduced into the room corner fire test.Heat release rate and flashover time were calculated and compared with those from experiment,and favorable agreement was found for the ply- wood with the thicknesses of 5mm,9mm and 12mm.
What problem does this paper attempt to address?