Hydrodynamic Behaviors of a Bubble-Up Loop Membrane Bioreactor

Bo LI,Bao-guo WANG
DOI: https://doi.org/10.3321/j.issn:1003-9015.2006.06.004
2006-01-01
Abstract:Based on the combination of the air-lift loop reactor (ALR) with the membrane bioreactor (MBR), a bubble-up loop membrane bioreactor was proposed, and its hydrodynamic behaviors were studied. A simulation system was applied to test the membrane separation performances. The gas hold-up and liquid circulation velocity were measured, and the influence of the hollow fiber membrane elements filled in the downer of the reactor on the hydrodynamic behaviors of the circulation was studied. The experimental results show that the two phase circulation can reduce the membrane fouling and increase the permeation flux simultaneously. In order to supply the driving force for membrane permeation, the bioreactor proposed can be operated under pressure, and it can reduce the energy consumption and equipment investment of the water treatment process. The experiments also show that the gas hold-up and liquid circulation velocity decrease with increasing the operating pressure. Based on theoretical analysis, a mathematical model was developed to describe the relationship of the average gas hold-up and liquid circulation velocity with the operation parameters, such as the pressure and the apparent gas velocity.
What problem does this paper attempt to address?