Electro-optic sampling method using high DC voltage applying setup

Yongwoon Parc,Changbum Kim,Jungyun Huang,Jangho Park,Sungju Park,Insoo Ko,Xiang Dao
2006-01-01
Abstract:A RF photo-cathode (RF PC) gun with 1.6 cell cavity is installed at GTS(Gun Test Stand) being built at the Pohang Accelerator Laboratory (PAL). The short, intense, and low emittance electron beams are produced by the RF PC gun. For the successful construction of PAL-XFEL, the timing jitter and bunch length of the beam at the exit of the gun should be measured accurately. EOS (Electro-Optic Sampling) is a very promising method to measure the jitter without any interference with the electron beam. The spatially resolved method will be used in this experiment, which is a single shot measurement using cooled CCD carmera due to very low energy. Before the measurement with the beam at the exit of the gun, the calibration experiment is done with DC high voltage applying setup with 1mm thick ZnTe crystal. The broadening of our laser pulse by the ZnTe crystal will be measured with auto-correlation method to know the resolution limit in this experiment and to do data analysis properly. In this presentation, the result of calibration experiment will be presented with a description of the experiment in detail and simulation result for low energy beam.
What problem does this paper attempt to address?