Flow Pipe's Plug-Removing of Benthic Meiobenthos Separating Device

LI Shi-lun,YANG Jing-qiang,YANG Jun-yi,YE Shu-ming,CHEN Ying
DOI: https://doi.org/10.3785/j.issn.1008-973x.2006.02.029
2006-01-01
Abstract:A rotating liquid jet method based on the cramming and structure characteristics of porous was proposed to resolve the cramming problem in the design of benthic meiobenthos separating device.Applying computational fluid dynamics(CFD) software to simulate the flow pipe of the separating device revealed the velocity field around the porous capillary and the reasons causative for the cramming of the porous capillary were analyzed.The plug-removal mechanisms of high pressure water jet and flow cytometer were compared.Application of the improved test specimen machine based on the plug-removal effect of high pressure and stirring motion showed that it was effective for plug-removal and that there was no stopping up case occurring during work.The rotating liquid jet method characterized by simple structure and good plug-removal effect is one of the good methods for porous capillary plug-removal.
What problem does this paper attempt to address?