Influence of heart rate on vessel visibility in CT coronary angiographyusing 64-slice spiral CT

Ji-chen WANG,Jian-xing QIU,Xiao-wei SUN,Li GAO,Jian-xin LIU,Guang-jian TANG,Xue-xiang JIANG
DOI: https://doi.org/10.3321/j.issn:1003-3289.2006.10.009
2006-01-01
Abstract:Objective: To evaluate the influence of heart rate on the image quality of coronary angiography by 64-slice computed tomography (MSCT). Methods: In 100 patients with suspected coronary artery diseases or after treatment as coronary artery diseases, ECG-gated coronary CT angiography (CTA) was performed with a 64slice MSCT Scanner. No β-blocker was administrated in all patients. Fifteen coronary segments were analyzed in each patient according to American Heart Association classification. The segments with the diameter ≥2 mm were included in final analysis. The image quality was defined as type I - no artifact; type II: mild artifact, but assessable; type III: severe artifact, unassessable for the vessel. Multiple regression and fisher's exact analysis was used to statistics study. Results: One thousand three hundreds and fifty-three segments in 100 patients had the diameter ≥2 mm. The image quality of coronary artery CTA was mainly affected by patients' heart rate. When the heart rate was less than 60/min, no artifact was found in the image; when its range was from 60 to 70 beats per minute (bpm), mild artifact was detected in 11.2% patients; when it was larger than 70 bmp, 58.6% patients had mild artifact, and one patient had severe artifact in one segment. Meanwhile, following the heart rate increased, the post-processing time for the patient augmented. Conclusion: Although the image quality of coronary artery CTA with MSCT is improved, vessel visibility is still highly dependent on the patients heart rate. The higher HR means possibly more artifacts in the vessels, and longer post-processing time.
What problem does this paper attempt to address?