Operation Characteristics of Treating Surface Water with Polyvinylchloride Hollow Fiber Ultrafiltration Membrane

Xiaoyan Guo,Zhenjia Zhang,Lin Fang,Liguo Su,郭晓燕,张振家,方林,苏立国
2006-01-01
Transactions of Tianjin University
Abstract:A pilot plant study on a polyvinylchloride hollow fiber ultrafiltration membrane process was conducted for treating surface water. The membrane system was operated in the dead-end filtration mode under different constant permeate fluxes. The results show that the optimized operation (transmembrane pressure ≤ 0.1 MPa, filtration times ≤ 30 min) with a hydraulic cleaning (30 s) and a chemical cleaning (30 min, the chemical cleaning was performed after 16 cycles of filtration) ensures a quite steady flux (1100 L/(m2·h·MPa)) and good permeate quality (turbidity < 0.1 NTU). A full-scale plant can be suggested to operate with a mixed strategy of constant permeate flux mode (transmembrane pressure ≤ 0.1 MPa) and constant transmembrane pressure mode. When the temperature of raw water becomes below 5°C, a constant transmembrane pressure mode should be used; otherwise a constant permeate flux mode (transmembrane pressures ≤ 0.1 MPa) can be operated. In this way, irreversible fouling of ultrafiltration membrane can be minimized to keep a stable flux and make the life of membrane longer.
What problem does this paper attempt to address?