TREATMENT OF PHARMACEUTICAL INTERMEDIATE SECONDARY EFFLUENT USING PVDF TUBULAR MEMBRANE

WU Li,XU Zhen-liang,ZHANG Juan,FENG Fei,CHENG Liang
DOI: https://doi.org/10.16796/j.cnki.1000-3770.2009.02.021
2009-01-01
Abstract:PVDF tubular ultrafiltration membranes with cutoff molecular weight of 100 000Dalton (Membrane A) and 50 000Dalton (Membrane B) were used for the pre-treatment of the pharmaceutical intermediate biochemistry drainage. The effect of trans-membrane pressure, feed flow velocity, temper- ature, pH and membrane fouling on the UF processes was analyzed. The results showed that Membrane B was better than Membrane A. The constant flux was 50 L·m-2·h-1 at a trans-membrane pressure of 0.12 MPa, feed flow velocity of 3.4 m·s-1, a temperature of 14℃ and pH value of 6~8. The peri- od of chemical cleaning was 72 hours. The average rejection ratio of COD was 25.5%. The average rejection ratio of aniline was 40.5%. The turbidity of permeate was lower than 0.5NUT while SDI was lower than 1.5. These results met the requirement of RO feed flow quality. Besides, the recovery effi- ciency of pure water for Membrane B was more than 80% after membrane cleaning by NaOH solution which pH was 12. It had a good repeatability.
What problem does this paper attempt to address?