A Method Combining the MMF Technique with Ultrasonic to Inspect the Wall Thickness for Water-wall Tube

Xiaochun Song,Songling Huang,Wei Zhao,Yihua Kang
DOI: https://doi.org/10.3321/j.issn:1004-132X.2006.10.023
2006-01-01
Abstract:Wall thickness is a key index for water-wall tube inspection in power plant, in order to inspect the tube quickly and evaluate the wall thickness quantitatively, a new method combining the magnetic main flux(MMF) with ultrasonic technique was proposed. The magnetic technique was used to do full inspection and locate the flaws, and the ultrasonic was employed to implement further quantitative inspection accurately. Then, the data measured by ultrasonic transducer was used to calibrate the MMF model parameters firstly, and a function was specified to fit the relations between the wall thickness and the peak value of MMF signal, thus the wall thickness can be evaluated quickly. The experimental results demonstrate that the model used in this system has better accuracy than the statistics relation model obviously, and it is suitable for defect evaluation in real-time.
What problem does this paper attempt to address?