Research on the mean heat transfer coefficients for the composite wall and roof of wood structure

Wang Zhao-Jun,Zhang Su-Mei,Wang Hai-Yun,Zhang Hou
2005-01-01
Abstract:The composite wall and roof for a full-scale wood structure house are composed of several different materials, and the materials are different both along the heat flux and the horizontal direction. So it is important to evaluate the heat performance of the envelope. Two models are set up to calculate the heat transfer coefficients for the wall and roof of the house. According to these two models, the heat transfer coefficient of the wall is 0.51 W/(m2K), and for the roof is 0.46 W/(m2K) which doesn't satisfy the standard. So the thickness of the wood structure for the wall should be changed from 100 mm into 140 mm, and that for the roof should be changed from 120 mm into 200 mm. The new heat transfer coefficients for the wall and roof are 0.38 W/(m2K) and 0.29 W/(m2K), respectively. And the results meet the requirements of energy conservation of 50%.