Improvement Analysis of the Main Stop and Governing Valve System of a 600MW Turboset

Ru-bo SANG,Hui-min MA,Song-qiang ZHU,Jian-hua XIN
DOI: https://doi.org/10.3321/j.issn:1000-6761.2005.04.005
2005-01-01
Abstract:Targeting at the test measured high pressure-loss of the main stop and control valve system of a 600 MW turboset in a certain power plant during its operating, two improvements have been suggested. One is to exchange the filter of the main stop valve for one with a larger passage area and the other is to improve that part of the governing valve disc's profile which lies beneath its point of contact. Calculating results of these two ways of improvement show that the total pressure loss may herewith decrease from 6.35% to 4.2%, which means as much as by 30%. Furthermore neither requires any change of the valve's fixed parts and neither will affect the control system and the actuator's stroke in any way. They are therefore both easy to implement with obvious economical benefits.