Design, fabrication and micro-PIV measurement on no-moving-part micro-pump

Fei WANG,Jian WANG,Feng HE
DOI: https://doi.org/10.3969/j.issn.1672-9897.2005.03.014
2005-01-01
Abstract:In order to simplify the fabrication process and prolong the working time of the micro-pump, the different kinds of no-moving-part micro-pumps were designed according to the flow characteristics of special tubes.The method of CFD was employed to optimize the micro-pump structures.The micro-pumps with the material PDMS were fabricated by micromachining processes.The micro-PIV technology was introduced to investigate the flow characteristics and measure the flow rate of the micro-pump.The micro-pump can transfer fluid in flow rate of 0.01~0.1μL/s at the driving frequency of 600~2000Hz.