300MW BOILER QUASI-THREE-DIMENSIONAL TEMPERATURE FIELD FAST RECONSTRUCTION BASED ON INTERPOLATED FILTER BACK PROJECTION METHOD

HUANG Qun-xing,MA Zeng-yi,YAN Jian-hua,CHI Yong,WANG Fei,CEN Ke-fa
DOI: https://doi.org/10.3321/j.issn:0258-8013.2005.06.025
2005-01-01
Abstract:D temperature field determination of pulverized boiler based on radiative propagation and projection reconstruction model provides a new technique for power plant combustion diagnosis. Filter back projection algorithm was provided to achieve on-line computing of radiative intensity distribution based on two-dimensional rectangle interpolation formula. The radiative intensity projection data got from spectrum-band-emendate flame image was interpolated for filtered back projection to compute intensity distribution, and emendated colorimetry method was used to calculate temperature value in each grid. Finally OpenGL technique was used to demonstrate the three-dimensional temperature field. The 300WMe power plant in-situ experiment results showed this algorithm achieved on-line combustion diagnostic monitor requirement.
What problem does this paper attempt to address?