Full Scale Fire Test on Single-Seat Sofa in Standard Single Room

杨昀,张和平,徐亮,王蔚,朱五八
DOI: https://doi.org/10.3321/j.issn:1006-8740.2004.05.009
2004-01-01
Abstract:The room fires mainly caused by upholstered furniture threaten human life and property. This paper investigated the combustion behaviors of single-seat sofa and fire dynamic parameters in a compartment. The full scale fire tests were conducted in the standard single room accorded with ISO 9705, whose inner dimensions are 3.6 m × 2.4 m × 2.4 m. Fire parameters such as the heat release rate and mass loss rate of the burning sofa and temperature profiles of inner room, were measured. The relationships among the fire parameters were studied. The results show that there is a nonlinear relationship between the heat release rate and the mass loss rate of the sofa.
What problem does this paper attempt to address?