Diagnostic Pit Width of the Optical Disk Information Mark

王玉英,熊剑平,马骋,菅冀祁,贾惠波
DOI: https://doi.org/10.3321/j.issn:1002-1582.2004.03.028
2004-01-01
Optical Technique
Abstract:The surface storage density is decided by the transverse size of the optical disk information mark (TSODIM) in the optical disk storage systems. The research present the focuses on finding the optimal pit width of the information mark (OPWIM) corresponding to the optimal modulation. The two dimensional foursquare grating is adopted as optical disk model. Effects of TSODIM on the modulation of the readout signal are analyzed by the emulation calculation of three-dimensional vector diffraction theory, and the OPWIM can be educed. The results are compared with the qualitative analysis of the scalar diffraction theory. Comparing the results of the two theories, the conclusions can be made as the followings: firstly, the optimal readout signal modulation will occur when the area of an information mark is a little less than half of that of the readout beam spot according to the scalar diffraction theory. Secondly, OPWIM, viz. the diagnostic pit width, is decided by the optical system of the optical disk readout system. Thirdly, quantitative calculation of the vector diffraction theory, which is accordant with the scalar diffraction theory, is closer to the trim size. Lastly, the scalar theory can still be used for the qualitative analysis because of its briefness, though it will result in great errors in quantitative calculation.
What problem does this paper attempt to address?