The thermal condition analysis of stage separation for a multistage solid rocket before the nozzle exit cone extend

韩丽霞,田维平,乐发仁,余贞勇
DOI: https://doi.org/10.3969/j.issn.1006-2793.2004.01.004
2004-01-01
Abstract:The thermal condition of stage separation for a multistage solid rocket with extendible nozzle was analyzed by means of flow computation software FLUENT and the turbulent flow model RNG κ-ε. The results indicate that characteristics of the wake flow in the extendible nozzle change significantly when the wake flow is blocked by the adapter cylinder, the forward dome and the exit cone, especially when a backflow comes into due to effect of the forward dome of the first stage motor and a shock wave forms in the nozzle. The thermal condition parameters calculated can provide references to the thermal-protection design of the solid motor.
What problem does this paper attempt to address?