Experimental investigation of dual-feed recirculation in cryogenic propellant transfer system

张亮,林文胜,鲁雪生,顾安忠
DOI: https://doi.org/10.3321/j.issn:1001-4055.2004.01.014
2004-01-01
Abstract:The main purpose of this paper is to use a dual-feed recirculation system to inhibit geyser in cryogenic propellant transfer system. A modeling experiment was made with liquid nitrogen as a working fluid. The effects of different insulation, tank pressure and injection situations on the precooling process were investigated. The differential pressure and wall temperature distribution of transfer pipe were recorded. From the result, it is clear that the nature circulation occurs in the recirculation utilizing dual-feed system. The method of experiment can provide possible way to reduce or eliminate geyser in cryogenic propellant transfer system.
What problem does this paper attempt to address?