On Improving Cooling Effectiveness of Lamilloy with Infrared Technique

全栋梁,李江海,刘高文,刘松龄,许都纯
DOI: https://doi.org/10.3969/j.issn.1000-2758.2004.05.004
2004-01-01
Xibei Gongye Daxue Xuebao/Journal of Northwestern Polytechnical University
Abstract:Lamilloy research attracts increasingly the attention of aeronautical powerplant engineers, both at home and abroad. Since 1998, we have engaged in research on Lamilloy to improve its cooling effectiveness. This research requires painstaking planning and execution of experimental investigation and careful analysis of experimental results. We made and tested three typical configurations of Lamilloy in a large-scale low-speed close-looped wind tunnel by infrared thermography. We obtained detailed two-dimensional contour maps of temperature and cooling effectiveness. The experimental results show that very high cooling effectiveness can be achieved with Lamilloy. The hole area ratio of Lamilloy plays the most important role in determining cooling effectiveness; the bigger the ratio, the higher is the cooling effectiveness. We derived a non-dimensional parameter f for analyzing cooling effectiveness. We find that in optimizing the design of Lamilloy, three parameters are important: parameter f, the adiabatic effectiveness of film cooling at gas side, and the internal heat transfer efficiency of Lamilloy configuration. We discuss in much detail how these three parameters should be dealt with in optimizing Lamilloy design. Although infrared technique began to be employed in heat transfer research only a few years ago, we believe that it has a promising future for assessing the relative cooling effectivenesses of different configurations of Lamilloy.
What problem does this paper attempt to address?