A COMBINED TOPOLOGY WITH BACK-UP BOOST AND ASYMMETRICAL HALF BRIDGE FOR FRONT END DC-DC CONVERTER

邢岩,黄立培,孙晓东
DOI: https://doi.org/10.13334/j.0258-8013.pcsee.2004.06.031
2004-01-01
Abstract:Holdup time is a special requirement for front-end DC-DC converter in distributed power supplies. It requires the converter to operate in a wide input voltage range, which greatly degrades the converter's normal efficiency. A back up boost and asymmetrical half bridge combined topology with a special control, for front-end DC-DC conversion, is proposed. The back up boost unit operates inherently only during the hold up time to ensure the input voltage for the asymmetrical half bridge, the normal power stage, within a narrow range and stands by under normal condition with no power loss. Therefore the combined converter can be designed in a very small size. And no spike is induced during operation modes switching of the converter. As a result, the overall performances of high efficiency, high power density and sufficient holdup time are obtained for the proposed converter. The topology and operation principles are analyzed, and simulated and experimental results are given.