Experimental Evaluation Of Pool Evaporation Models

Xuhai H. Pan,Juncheng Jiang,Hongwei Gong
2004-01-01
Abstract:According to benzene evaporation experiments in wind tunnel, the widely used evaporation models, such as Mackay & Matsugu model, GRAY model, BAU model, SUBTEC model, EPA model, NIOH-1 model and NIOH-2 model, were evaluated. The results shown that only the evaporation rate predicted by EPA model and NIOH-1 model were no more than measured. Mackay & Matsugu model and SUBTEC model were very suitable for constituting. safety procedures. About modeling veracity, errors between results predicted by Mackay 4 Matsugu model, NIOH-1 model and SUBTEC model and measured were little. Errors of Mackay & Matsugu model and NIOH-1 model were about 10% and 17%, respectively. NIOH-1 model and BAU model were fit to the situation of less wind speed or laminar flow. And NIOH-2 model, GRAY model and SUBTEC model were fit to the situation of greater wind speed or turbulent flow. Moreover, Mackay & Matsugu model and EPA model were fit to all situations.
What problem does this paper attempt to address?